PE71S6102 | 1M |
40 GHz |
SPDT |
F |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6103 | 1M |
40 GHz |
SPDT |
F |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6104 | 1M |
40 GHz |
SPDT |
I, F, TTL |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6105 | 1M |
40 GHz |
SPDT |
I, F, TTL |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6106 | 1M |
40 GHz |
SPDT |
L |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6107 | 1M |
40 GHz |
SPDT |
L |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6108 | 1M |
40 GHz |
SPDT |
I, L, TTL |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6109 | 1M |
40 GHz |
SPDT |
I, L, TTL |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6134 | 1M |
40 GHz |
SP4T |
N |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6135 | 1M |
40 GHz |
SP4T |
N |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6136 | 1M |
40 GHz |
SP4T |
N, I, TTL |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6137 | 1M |
40 GHz |
SP4T |
N, I, TTL |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6138 | 1M |
40 GHz |
SP4T |
L |
60 |
0.5 |
35 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6139 | 1M |
40 GHz |
SP4T |
L |
60 |
0.5 |
35 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6142 | 1M |
40 GHz |
SP6T |
N |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6143 | 1M |
40 GHz |
SP6T |
N |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6144 | 1M |
40 GHz |
SP6T |
N, I, TTL |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6145 | 1M |
40 GHz |
SP6T |
N, I, TTL |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6146 | 1M |
40 GHz |
SP6T |
L |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6147 | 1M |
40 GHz |
SP6T |
L |
60 |
0.5 |
35 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6148 | 1M |
40 GHz |
SP6T |
L, I, TTL |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6149 | 1M |
40 GHz |
SP6T |
L, I, TTL |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6118 | 1M |
40 GHz |
Transfer |
F |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6119 | 1M |
40 GHz |
Transfer |
F |
60 |
0.5 |
20 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6120 | 1M |
40 GHz |
Transfer |
I, F, TTL |
60 |
0.5 |
20 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6121 | 1M |
40 GHz |
Transfer |
I, F, TTL |
60 |
0.5 |
20 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6122 | 1M |
40 GHz |
Transfer |
L |
60 |
0.5 |
20 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6123 | 1M |
40 GHz |
Transfer |
L |
60 |
0.5 |
20 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6124 | 1M |
40 GHz |
Transfer |
I, L, TTL |
60 |
0.5 |
20 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6125 | 1M |
40 GHz |
Transfer |
I, L, TTL |
60 |
0.5 |
20 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6140 | 1M |
46 GHz |
SP4T |
L, I, TTL |
60 |
0.5 |
15 |
12 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
![]() |
PE71S6141 | 1M |
46 GHz |
SP4T |
L, I, TTL |
60 |
0.5 |
15 |
28 |
10 |
Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
* Features:
I = Indicators
F = Failsafe
L = Latching Feature
TTL = TTL Control Feature
N = Normally Open
S = Self Cutoff
T = Terminated
H = Hot Switching
P = Pulse Latching
パスタナック製品の詳細はこちらをクリックするとご覧になれます
© Pasternack Enterprises, Inc. 1999-2017
Pasternack Enterprises, Inc.
お問合せは日本総代理店
エム・アールエフ(株)へ。
Eメールpasternack@mrf.co.jp
フリーダイヤル (0120) 217-339
FAX: (03) 3258-2030